Blog / Meetings & Events

Meetings & Events: Penumbra Announces Key Events at ISET 2020

January 17, 2020
red rectangle with text "ISET 2020"

Penumbra Announces Key Events at International Symposium on Endovascular Therapy (ISET) 2020 Meeting

Penumbra, Inc. is pleased to announce key events at the upcoming International Symposium on Endovascular Therapy (ISET) Meeting to be held January 22-25 at the Diplomat Hotel in Hollywood, FL.

Attendees will have the opportunity to learn more about Penumbra’s Indigo® System, Penumbra ENGINE, Ruby® Coil, POD®, Packing Coil, and LANTERN® devices by visiting Penumbra Booth 203. Penumbra will also introduce its newest low profile embolization platform, LP System; and the new Indigo System treatment indication for pulmonary embolism. Penumbra will exhibit from 11:00 a.m. to 2:00 p.m. on Thursday, January 23, and 11:00 a.m. to 4:00 p.m. on Friday, January 24.

 

Lunch Symposium
Friday, January 24, 12:45 to 2:00 p.m.
DIPLOMAT 3

  • Latest Endovascular Technologies in Thrombectomy and Embolization

Speakers:

— James Benenati, M.D., Miami Cardiac & Vascular Institute, FL

— Parag Patel, M.D., Medical College of Wisconsin, WI

— Chris Metzger, M.D., Holston Valley Medical Center, TN

 

About Penumbra’s Vascular Products
Penumbra has a growing suite of thrombectomy and embolization products for use in a range of peripheral and coronary vasculature conditions:

Blog Illustration of Ruby Coil, Packing Coil, and Pod in vessels with text reading "Ruby® Coil. Packing Coil. Pod®"

Penumbra’s embolization platform includes Ruby Coil, with sizes ranging from 2 mm to 40 mm diameter and up to 60 cm in length; POD, engineered to perform vessel sacrifices by anchoring in vessel; and Packing Coil, which is uniquely designed to pack densely behind Ruby and POD to occlude arteries and veins throughout the peripheral vasculature, including aneurysms.

 

Image of LANTERN Delivery Microcatheter with test reading "LANTERN Microcatheter"

The LANTERN Microcatheter is designed to assist in the delivery of diagnostic agents, such as contrast media, and therapeutic devices, such as occlusion coils, to the peripheral vasculature. It is offered in a variety of lengths and tip shapes.

Blog image of Indigo System & illustration of CAT8 in a vessel with text reading " CAT™8. Penumbra ENGINE™"

The Indigo System is a continuous aspiration thrombectomy system designed for the removal of fresh, soft emboli and thrombi from the peripheral arterial and venous systems, and for the treatment of pulmonary embolism, and includes catheter sizes: CAT8, CATD, CAT6, CAT5, and CAT3. The latest generation of the Indigo System features Indigo System CAT RX and Separator 4 indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Indigo CAT RX, a rapid exchange platform, received 510(k) clearance in May 2017 and launched in 2018.

Blog Image containing 4 different Indigo System Catheters with text reading "CATD. CAT6. CAT RX. CAT5&3"

The aspiration catheters are paired with Penumbra ENGINE, our proprietary continuous, mechanical vacuum aspiration pump that received 510(k) clearance in March 2018. The Indigo System’s proprietary Separator technology is designed to enable unobstructed aspiration for the duration of the procedure.

 

Risk Information
Caution: Federal (USA) law restricts these devices to sale by or on the order of a physician. Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use.

 

INDIGO Aspiration Catheters and Separators — Indication for Use
As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism.

INDIGO Aspiration Tubing — Indication for Use
As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump.

Penumbra Aspiration Pump — Indication for Use
The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems.

Contraindications
Not for use in the coronaries or the neurovasculature.

Warnings
• The INDIGO Aspiration System should only be used by physicians who have received appropriate training in interventional techniques.
• Do not advance, retract or use any component of the INDIGO System against resistance without careful assessment of the cause using fluoroscopy. If the cause cannot be determined, withdraw the device or system as a unit. Unrestrained torquing or forced insertion of the catheter or SEPARATOR against resistance may result in damage to the device or vessel.
• Do not use the INDIGO Aspiration System with a pump other than the Penumbra Aspiration Pump.
• Placing guidewire too distal in the pulmonary vasculature or excessive manipulation of aspiration/guiding catheter in the smaller, peripheral, and segmental pulmonary artery branches can result in vessel perforation.

Precautions
• The device is intended for single use only. Do not resterilize or reuse.
• Do not use kinked or damaged devices. Do not use open or damaged packages. Return all damaged devices and packaging to the manufacturer/distributor.
• Use prior to the “Use By” date.
• Use the INDIGO Aspiration System in conjunction with fluoroscopic visualization.
• Maintain a constant infusion of appropriate flush solution.
• When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove thrombus. Excessive aspiration or failure to close the INDIGO Aspiration Tubing when aspiration is complete is not recommended.
• Hemoglobin and hematocrit levels should be monitored in patients with >700 mL blood loss from the clot aspiration procedure.
• The INDIGO SEPARATOR is not intended for use as a guidewire. If repositioning of the INDIGO Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard catheter and guidewire techniques.
• Do not use automated high-pressure contrast injection equipment with the INDIGO Aspiration Catheter because it may damage the device.

Potential Adverse Events
Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia; arteriovenous fistula; cardiac injury; cardio-respiratory arrest; death; device malfunction; distal embolization; emboli; excessive blood loss; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; hemoptysis; respiratory failure; thromboembolic events.

 

The INDIGO CAT RX Aspiration Catheters and INDIGO SEPARATOR 4 — Indication for Use
As part of the INDIGO Aspiration System, the INDIGO CAT RX Aspiration Catheters and INDIGO SEPARATOR 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature.

The INDIGO Aspiration Tubing — Indication for Use
As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO CAT RX Aspiration Catheters to the Penumbra Aspiration Pump.

Penumbra Aspiration Pump — Indication for Use
The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems.

Contraindications
The INDIGO Aspiration System is contraindicated in:
• The removal of fibrous, adherent or calcified material (e.g. chronic clot, atherosclerotic plaque).
• The cerebral vasculature.

Warnings
• The INDIGO Aspiration System should only be used by physicians who have received appropriate training in interventional techniques.
• Do not advance, retract or use any component of the INDIGO System against resistance without careful assessment of the cause using fluoroscopy. If the cause cannot be determined, withdraw the device or system as a unit. Unrestrained torquing or forced insertion of the catheter or separator against resistance may result in damage to the device or vessel.
• Do not use the INDIGO Aspiration System with a pump other than the Penumbra Aspiration Pump.

Precautions
The safety and effectiveness of this device for use in the treatment of ST-Elevation Myocardial Infarction (STEMI) has not been established. Complications from the use of this device in this manner could lead to death, permanent impairment, and/or the need for emergency medical intervention.
• The device is intended for single use only. Do not resterilize or reuse. Resterilization and/or reuse may result in ineffective catheter coating lubrication, which may result in high friction and the inability to access the target vasculature location.
• Do not use kinked or damaged devices. Do not use open or damaged packages. Return all damaged devices and packaging to the manufacturer/distributor.
• Use prior to the “Use By” date.
• Use the INDIGO Aspiration System in conjunction with fluoroscopic visualization.
• Maintain a constant infusion of appropriate flush solution.
• When performing aspiration, ensure that the INDIGO Aspiration Tubing valve is open for only the minimum time needed to remove thrombus. Excessive aspiration or failure to close the INDIGO Aspiration Tubing valve when aspiration is complete is not recommended.
• The INDIGO SEPARATOR 4 is not intended for use as a guidewire. If repositioning of the INDIGO CAT RX Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard guidewire techniques.
• Do not use INDIGO SEPARATOR 4 to macerate or retrieve thrombus distal to the catheter tip. INDIGO SEPARATOR 4 is intended to be used with INDIGO CAT RX Aspiration Catheter to clear the distal end of the catheter lumen should it be blocked with thrombus.
• Do not use automated high-pressure contrast injection equipment with the INDIGO CAT RX Aspiration Catheter because it may damage the device.

Potential Adverse Events
Possible complications include, but are not limited to, the following:
allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events.

 

PENUMBRA ENGINE — Indication for Use
The PENUMBRA ENGINE is indicated as a vacuum source for Penumbra Aspiration Systems.

Contraindications
There are no contraindications.

Warnings/Precautions
• The canister is intended for single use only. Do not reuse. Reuse may result in canister cracking or vacuum filter blockages, which may result in the inability to aspirate.
• Do not block bottom air vents. Unit may overheat and shut off or fail to restart if run for extended periods of time without airflow.
• To avoid the risk of electrical shock, this equipment must only be connected to a supply mains with protective earth.
• Do not position the PENUMBRA ENGINE so that it is difficult to remove the power cord. The means of mains disconnect is to remove the power cord.
• Only use replacement fuse with correct rating (see Table 1 for fuse rating).
• Remove and service the PENUMBRA ENGINE if liquids or solids have been drawn into the PENUMBRA ENGINE.
• Do not use in the presence of a flammable anesthetic mixture with air or nitrous oxide.
• Do not use in an oxygen rich environment.
• To prevent fire or shock hazard, use a replacement power cord of equal rating.
• Do not re-infuse blood or fluid from the canister back into the patient.
• Do not use petroleum based compounds, acids, caustics, or chlorinated solvents to clean or lubricate any parts. It will reduce the service life of the PENUMBRA ENGINE. Use only water-based solvents for cleaning.
• Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
• Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 inches (30cm) to any part of the PENUMBRA ENGINE. Otherwise, this could result in degradation of the performance of this equipment.
• Common emitters (such as RFID emitters, security systems, diathermy equipment, and portable transmitters) should not be used in close proximity to the PENUMBRA ENGINE as they can interfere with and result in degradation of the performance of the equipment.
• Equipment is not safe for MR use.
• No modification of this equipment is allowed.

 

RUBY Coil System — Indication for Use
The RUBY Coil System is indicated for arterial and venous embolizations in the peripheral vasculature.

Contraindications
There are no known contraindications.

Warnings
The RUBY Coil System should only be used by physicians who have received appropriate training in interventional techniques.

Precautions
• The device is intended for single use only. Do not resterilize or reuse. Resterilization and/or reuse may compromise the structural integrity of the device or increase the risk of contamination or infection leading to device failure and/or cross-infection and potential patient injury, illness, or death.
• Do not use kinked or damaged devices. Do not use opened or damaged packages. Return all damaged devices and packaging to the manufacturer/distributor.
• Use prior to the “Use By” date.
• Use device in conjunction with fluoroscopic guidance.
• Do not advance or retract the device against resistance without careful assessment of the cause using fluoroscopy.
• Moving or torquing the device against resistance may result in damage to the vessel or device.
• Maintain a constant infusion of appropriate flush solution.

Potential Adverse Events
Potential complications include but are not limited to: acute occlusion; air embolism; allergic reaction and anaphylaxis from contrast media; aneurysm rupture; arteriovenous fistula; coagulopathy; coil herniation into parent vessel; death; device malfunction; distal embolization; emboli; embolic stroke and other cerebral ischemic events; false aneurysm formation; hematoma or hemorrhage at access site of entry; incomplete aneurysm occlusion; infection; intima dissection; intracranial hemorrhage; ischemia; myocardial infarction; neurological deficits including stroke; parent artery occlusion; peripheral thromboembolic events; post-embolization syndrome; premature device detachment; recanalization; renal failure; respiratory failure; revascularization; thromboembolic episodes; vessel spasm, thrombosis, dissection, or perforation.

 

POD System — Indication for Use
For POD Coils with nominal sizes ≤ 6 mm
The POD System is indicated for the embolization of:
• Intracranial aneurysms.
• Other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae.
• Arterial and venous embolizations in the peripheral vasculature.

For POD Coils with nominal sizes > 6 mm
The POD System is indicated for arterial and venous embolizations in the peripheral vasculature.

Contraindications
There are no known contraindications.

Warnings
The POD System should only be used by physicians who have received appropriate training in interventional techniques.

Precautions
• The device is intended for single use only. Do not resterilize or reuse. Resterilization and/or reuse may compromise the structural integrity of the device or increase the risk of contamination or infection leading to device failure and/or cross-infection and potential patient injury, illness, or death.
• Do not use kinked or damaged devices. Do not use opened or damaged packages. Return all damaged devices and packaging to the manufacturer/distributor.
• Use prior to the “Use By” date.
• Use device in conjunction with fluoroscopic guidance.
• Do not advance or retract the device against resistance without careful assessment of the cause using fluoroscopy. If POD cannot be advanced or retracted, withdraw the device as a unit with the microcatheter.
• Moving or torquing the device against resistance may result in damage to the vessel or device.
• Maintain a constant infusion of an appropriate flush solution.

Potential Adverse Events
Possible complications include, but are not limited to, the following:
acute occlusion; air embolism; allergic reaction and anaphylaxis from contrast media; aneurysm rupture; arteriovenous fistula; coagulopathy; coil herniation into parent vessel; death; device malfunction; distal embolization; emboli; embolic stroke and other cerebral ischemic events; false aneurysm formation; hematoma or hemorrhage at access site of entry; incomplete aneurysm occlusion; infection; intima dissection; intracranial hemorrhage; ischemia; myocardial infarction; neurological deficits including stroke; parent artery occlusion; peripheral thromboembolic events; post-embolization syndrome; premature device detachment; recanalization; renal failure; respiratory failure; revascularization; thromboembolic episodes; vessel spasm, thrombosis, dissection, or perforation.

 

Penumbra Delivery Microcatheters — Indication for Use
The Penumbra Delivery Microcatheters are intended to assist in the delivery of diagnostic agents, such as contrast media, and therapeutic devices, such as occlusion coils to the peripheral and neuro vasculature.

Contraindications
There are no known contraindications.

Warnings
The Penumbra Delivery Microcatheters should only be used by physicians who have received appropriate training in interventional techniques.

Precautions
• The devices are intended for single use only. Do not resterilize or reuse. Resterilization and/or reuse may result in ineffective catheter coating lubrication, which may result in high friction and the inability to access the target location.
• Do not use kinked or damaged devices. Do not use open or damaged packages. Return all damaged devices and packaging to the manufacturer/distributor.
• Use prior to the “Use By” date.
• Use the Penumbra Delivery Microcatheters in conjunction with fluoroscopic visualization.
• Do not advance or withdraw the Penumbra Delivery Microcatheters against resistance without careful assessment of the cause using fluoroscopy. If the cause cannot be determined, withdraw the device. Moving or torquing the device against resistance may result in damage to the vessel or device.
• Maintain a constant infusion of an appropriate flush solution.
• If flow through the device becomes restricted, do not attempt to clear the lumen by infusion. Remove and replace the device.

Potential Adverse Events
Possible complications include, but are not limited to, the following: acute occlusion; hematoma or hemorrhage at access site; death; intracranial hemorrhage; hemorrhage; infection (at access site); distal embolization; ischemia (cardiac and/or cerebral); embolus (air, foreign body, thrombus, plaque); aneurysm perforation; false aneurysm formation; neurological deficits including stroke; vessel spasm, thrombosis, dissection, perforation or rupture; air embolism; emboli.

Questions?

Contact us to learn more about our products and company